fixed a bug with negative uv values
This commit is contained in:
@@ -206,14 +206,19 @@ class UVSensor:
|
||||
# scary computations ahead! refer to Vishay app note 84339 and Sparkfun
|
||||
# VEML6075 documentation.
|
||||
|
||||
# first, compensate for visible and IR noise
|
||||
# compensate for visible and IR noise
|
||||
aCorr = aRaw - 2.22 * c1 - 1.33 * c2
|
||||
bCorr = bRaw - 2.95 * c1 - 1.74 * c2
|
||||
|
||||
# second, convert values into irradiances
|
||||
a = aCorr * 0.00110
|
||||
b = bCorr * 0.00125
|
||||
# convert values into irradiances
|
||||
a = aCorr * 1.06
|
||||
b = bCorr * 0.48
|
||||
|
||||
# zero out negative results (readings with no uv)
|
||||
if a < 0:
|
||||
a = 0
|
||||
if b < 0:
|
||||
b = 0
|
||||
# last, calculate the UV index
|
||||
i = (a + b) / 2
|
||||
|
||||
|
||||